Related Experiment Video
Updated: Aug 30, 2026

Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
Pilot study: data-capturing consistency of two trans-tibial casting concepts, using a manikin stump model: a
A W P Buis1, A Blair, P Convery
1National Centre for Training and Education in Prosthetics and Orthotics, University of Strathclyde, Glasgow, Scotland, UK. arjan.buis@strath.ac.uk
Abstract:
The quality of fit of a trans-tibial patellar tendon bearing (PTB) socket may be influenced by consistency in casting, rectification or alignment. For this study two distinctive different data-capturing concepts were tested in relation to prosthetist performance. The hands-on PTB and hands-off ICECAST compact concept were studied and compared for inter- and intra-prosthetist consistency using a specially designed manikin stump model. A purpose designed digitiser was used to scan a selected surface area of the produced models, 5 for each concept, 10 in total. The extent of casting consistency at each of 936 locations per plaster model was calculated and the level of consistency was quantified. This study has shown that by using the manikin model there is a clear indication that the investigated hands-off concept produces more consistent results than the hands-on concept.