The effect of breathing pattern on nebulizer drug delivery
A P Roth1, C F Lange, W H Finlay
1Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada T6G 2G8.
Abstract:
The significance of using breathing patterns with simplified functional shapes in vented jet nebulizer research is examined. This study is comprised of three parts: (1) The measurement and analysis of human breathing patterns, (2) the subsequent in vitro testing of the effects of breathing pattern differences using a consistent bench test method, and (3) a computer modeling of these effects on the estimated regional drug deposition in the human lung. Breathing through a Pari LC-Star nebulizer caused statistically significant changes (p < or = 0.05) in measured human breathing patterns when compared to normal breathing. Observed changes included an increase in the tidal volume (34%) and period (39%). Additionally, the average duty cycle shifted 12% towards a more symmetrical breath due to the unequal increase in the inhalation and exhalation times (55% and 28%, respectively). The position of the point of maximum flow in each breath phase shifted towards the beginning and end of the breath for the inhale and exhale by 28% and 48%, respectively. The bench testing revealed that breathing pattern shape variation caused statistically significant differences in nebulizer output only in two cases. Decreasing duty cycles and shifting the point of maximum flow towards the beginning of the breath both result in a decrease in output efficiency. Square flow patterns produced slight but consistently higher output efficiencies (average 2.1% higher) and a constant output particle size over the course of each breath, different from the other non-square patterns. Numerical simulations revealed no significant dosage differences resulting from breathing pattern shape variations. However, square wave patterns consistently produced slight overpredictions in comparison with real nebulizer patterns. In contrast, sine wave patterns were found to produce essentially the same results as nebulizer patterns in both the bench tests and in the deposition simulations. This suggests that sine wave shapes are preferable for simulating breathing when bench testing drug delivery using vented jet nebulizers.
Related Concept Videos
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Drug Delivery: Enteral Route
Drugs in...
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs through the...