Related Experiment Video
Updated: Aug 8, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Solute clearance in continuous venovenous hemodialysis. A comparison of cuprophane, polyacrylonitrile, and
O C Ifediora1, B P Teehan, M H Sigler
1Division of Nephrology, Lankenau Hospital, Wynnewood, Pennsylvania.
Abstract:
Critically ill patients with ARF and MOSF were treated with continuous venovenous hemodialysis (CVVHD). The BSM 22 delivery system (CGH Medical, Denver, CO) and four different dialyzer membranes were used. Vascular access was achieved with a dual lumen catheter placed percutaneously into a large vein. Heparin was used for anticoagulation, and commercially available peritoneal dialysis fluid was used as dialysate. At a fixed blood flow rate of 100 ml/min, the dialysate inflow and outflow rates were regulated to control azotemia and fluid balance. Blood side and dialysate side clearances for urea nitrogen, creatinine, bicarbonate, and lactate were measured. All dialyzer membranes studied provided high urea nitrogen clearance approximating dialysate outflow rate and resulting in excellent control of azotemia. Some of the dialyzer membranes also had high creatinine and bicarbonate clearances. Bicarbonate loss was balanced by lactate uptake with all dialyzers. It is concluded that CVVHD is an efficient and safe therapy for acute renal failure, capable of maintaining nitrogen balance in patients with protein catabolic rates up to 2 g/kg/day. Urea nitrogen clearance is dependent upon dialysate outflow rate rather than the dialyzer membrane type or dialyzer flow geometry, and may prove to be the modality of choice for therapy of acute renal failure in unstable patients with MOSF.
More Related Videos
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
06:28Single Step Isolation of Extracellular Vesicles from Large-Volume Samples with a Bifurcated A4F Microfluidic Device
Published on: February 2, 2024
Related Concept Videos
Dialysis
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Continuous Renal Replacement Therapy
Hemodialysis II: Procedure and Complications