Related Experiment Video
Updated: Aug 30, 2026

Evaluation of the Curing of Adhesive Systems by Rheological and Thermal Testing
Published on: July 3, 2020
Compatibility of dental adhesives and dual-cure cements
Carmen Pfeifer1, Denise Shih, Roberto Ruggiero Braga
1Department of Dental Materials, School of Dentistry, University of São Paulo, Brazil.
Purpose:
To evaluate the extrusion shear strength of bonding between porcelain and dentin.
Methods:
The adhesives tested were Prime&Bond NT in both dual-cure and light-cure versions, Scotchbond Multi-Purpose Plus, One-Step and Single Bond. The cements evaluated were RelyX ARC and Enforce. Discs of bovine root dentin 2.5 mm thick had the canal prepared with a standardized taper. Porcelain truncated cones were bonded into the perforations. Cements were tested in dual-cure and self-cure mode. Extrusion shear strength test was performed after 48 hours storage in 37 degrees C distilled water. Data were analyzed by three-way ANOVA/Tukey's test.
Results:
Bond strength values ranged from 5.5 MPa to 8.9 MPa when cements were tested in dual-cure mode, and from 1.4 MPa to 6.9 MPa when tested in self-cure mode. Scotchbond Multi-Purpose Plus was the only adhesive to present similar results when associated with cements in dual-cure and self-cure modes. For the other adhesives, differences in bond strength from 33 to 76% were observed between dual-cure and self-cure modes.
Related Concept Videos
Mortar Properties
Curing of Concrete
Types of Cement II
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Soundness of Cement
Bonding and Strength of Aggregate