Related Experiment Video
Updated: Aug 30, 2026

Total Internal Reflection Absorption Spectroscopy (TIRAS) for the Detection of Solvated Electrons at a Plasma-liquid Interface
Published on: January 24, 2018
Studies of solvation in homogeneous and heterogeneous media by electronic spectroscopic method
Mrinmoy Shannigrahi1, Ramkrishna Pramanik, Sanjib Bagchi
1Department of Chemistry, Burdwan University, Burdwan 713104, India.
Abstract:
Solvation characteristics in homogenous (pure and mixed binary solvents) and heterogeneous media (aqueous micelles, beta- and gamma-cyclodextrine solutions) have been studied by monitoring the emission characteristics of a newly synthesised dye. The longest wavelength absorption and emission band of the dye arise due to transition between S(0) and S(1) state. The maximum energy of electronic transition involving intramolecular charge transfer is found to be dependent on both the hydrogen-bond donating ability and the polarity-polarisability in pure solvent. The dipole moment in the S(1) state, as determined by solvatochromic procedure, agrees well with the value obtained by theoretical calculation at the AM1 level. Preferential solvation of the dye by alcohols has been found to occur in ethanol+water, propan-1-ol+water, propan-2-ol+water binary mixtures. In aqueous micellar media the dye molecule is located at the water-micelle interface. The binding constant for the dye-micelle interaction has also been determined. The results have been compared with those for a structurally related symmetrical ketocyanine dye.
Related Concept Videos
Solubility
A solution is a homogeneous mixture composed of a solvent, the major component, and a solute, the minor component. The physical state of a solution—solid, liquid, or gas—is typically the same as that of the solvent. Solute concentrations are often described with qualitative terms such as dilute (of relatively low concentration) and concentrated (of relatively high concentration).
In a solution, the solute particles (molecules, atoms, and/or ions)...
UV–Vis Spectroscopy: Molecular Electronic Transitions
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
UV–Vis Spectrometers
Spectrophotometry: Introduction