Overloaded gradient elution chromatography on heterogeneous adsorbents in reversed-phase liquid chromatography
Fabrice Gritti1, Attila Felinger, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
Overloaded band profiles of phenol were measured on a C18-Kromasil column in gradient elution conditions. The mobile phase used was a mixture of methanol and water. The volume fraction of methanol was allowed to vary between 0 and 0.5. A general adsorption model, which expresses the amount of phenol adsorbed q* as a function of both its concentration C and the composition phi of the organic modifier (methanol) in the mobile phase, was empirically derived from previous independent adsorption experiments based on frontal analysis (FA) and frontal analysis by the characteristic point (FACP). Accordingly, the general model was an extension of the simplest heterogeneous model, the Bilangmuir model, to non-isocratic conditions. The low-energy sites followed the classical linear solvent strength model (LSSM), but not the high-energy sites whose saturation capacity linearly decreased with phi. The general model was validated by comparing the experimental and simulated band profiles in gradient elution conditions, in linear and non-linear conditions, as well. The band profiles were calculated by means of the equilibrium-dispersive model of chromatography with a finite difference algorithm. A very good agreement was observed using steps gradient (delta phi) from 0 to 50% methanol and gradient times t(g) of 20, 25, 30, 40, 60, 80 and 100 min. The agreement was still excellent for steps gradient from 5 to 45% (t(g) = 25 min), 5 to 35% (t(g) = 50 min), 5 to 25% (t(g) = 50 min) and 5 to 15% (t(g) = 50 min). Significative differences appeared between experience and simulation when the slope of the gradient (delta phi/t(g)) became too strong beyond 3.3% methanol per minute. This threshold value probably mirrored the kinetic of arrangement of the G18-bonded chains when the methanol content increased in the mobile phase. It suggested that the chromatographic system was not in a full thermodynamic equilibrium state when very steep mobile phase gradients were applied.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...