Related Experiment Video
Updated: Aug 25, 2026

Real-time Tracking of DNA Fragment Separation by Smartphone
Published on: June 1, 2017
Study of ethidium bromide effect on dsDNA separation by capillary zone electrophoresis and laser light scattering
Dehai Liang1, Jun Zhang, Benjamin Chu
1Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794, USA.
Abstract:
The effect of ethidium bromide (EB) on dsDNA separation was studied by using capillary zone electrophoresis (CZE) and laser light scattering (LLS). By increasing the concentration from 1 to 15 microg/mL, EB showed significant influence on the separation of pBR322 HaeIII in terms of resolution, speed, and signal-over-noise ratio. The physicochemical properties of DNA, such as mobility under electric field, charge-over-size ratio, and hydrodynamic radius, showed two declines, a sharp drop followed by a relaxed decrease, with increasing EB concentration. Such observations could be explained by using two modes of the dye binding process: intercalation and outside binding. The combination of results obtained from CZE and LLS also confirmed the existence of outside binding. Compared with intercalation, outside binding showed a weaker dye concentration dependence in neutralizing the negative charges on the DNA fragments. Static light scattering showed that
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

