[Predictive capability of the TCI Diprifusor system in patients with terminal chronic renal insufficiency]
S Sabaté Tenas1, J Soler Corbera, J M Queraltó Companyo
1Servicio de Anestesiología, Reanimación y Clínica del Dolor, Fundación Puigvert (IUNA), C/Cartagena 340, 08025-Barcelona. 29285sst@comb.es
Objective:
To evaluate the predictive capability of a target-controlled infusion (TCI) system in patients with terminal chronic renal failure by comparing real drug concentrations with predicted concentrations.
Methods:
Forty ASA II-III patients undergoing kidney transplants were enrolled and grouped by age: group A 18-54 years old and group B 55-80 years old. Propofol was administered through the Diprifusor TCI system (Astra Zeneca) with the target concentration of propofol for induction set at 3 micrograms/mL for group A patients and 2.5 micrograms/mL for group B patients. Arterial blood samples were taken for analysis of drug concentrations at the following times: 2 and 5 minutes after starting the infusion; immediately after the incision; before and 5 minutes after increasing or decreasing the target concentration > 25%; before and 5 minutes after switching off the perfusion for surgery; upon eye opening; and 30 minutes after switching off the infusion pump. The predictive capability of the system was determined by performance error (PE). We calculated bias (%, median PE) and accuracy (%, median absolute PE).
Results:
Twenty group A and 20 group B patients were studied. The median PEs in groups A and B, respectively, were -3.45 (-20.3-28.4) and -1.1 (-19.7-15.4). Median absolute PEs were 21.2 (11.9-45.1) and 16.3 (11.5-27.4), respectively.
Conclusions:
The results indicate that the predictive capability of the Diprifusor pharmacokinetic model is acceptable in patients with terminal kidney failure, given the minor bias of 10% to 20% and the degree of accuracy between 20% and 40%.
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...