Procedure for Human Saphenous Veins Ex Vivo Perfusion and External Reinforcement
Published on: October 1, 2014
Pressure-diameter relationship in the human greater saphenous vein
Wim Stooker1, Murat Gök, Pieter Sipkema
1Department of Cardiothoracic Surgery, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands. w.stooker@olvg.nl
Background:
Compliance of artificial and autologous vascular grafts is related to future patency. We investigated whether differences in compliance exist between saphenous vein grafts derived from the upper or lower leg, which might indicate upper or lower leg saphenous vein preference in coronary artery bypass surgery. Furthermore, the effect of perivenous application of fibrin glue on mechanical vein wall properties was studied to evaluate its possible use as perivenous graft support.
Methods:
Vein segments (N = 10) from upper or lower leg saphenous vein grafts were collected for histopathologic examination and smooth muscle cell/extracellular matrix (SMC/ECM) ratio was calculated. This ratio is suggested to be related with vascular elastic compliance. In a second group vein graft segments (N = 6) from upper and lower leg were placed in an in vitro model generating stepwise increasing static pressure up to 150 cm H(2)O. Outer diameter was measured continuously with a video micrometer system. Distensibility was calculated from the pressure-diameter curves. A third group of vein graft segments (N = 7) was pressurized after fibrin glue application to prevent overdistension, and studied in the same setup.
Results:
Vein segments from the lower leg demonstrated a consistent higher relative response compared with the upper leg saphenous vein graft (0.9176 +/- 0.03993 vs 0.5245 +/- 0.02512). Both reach a plateau in the high-pressure range (> 100 cm H(2)O). A significant difference in in vitro distensibility between upper and lower leg saphenous vein was only found at a pressure of 50 cm H(2)O (p < 0.05). With fibrin glue, support overdistension is prevented as revealed by the maximum relative response between fibrin glue supported upper and lower leg saphenous vein segments (0.4080 +/- 0.02464 vs 0.582 +/- 0.051), and no plateau is reached in the pressure range up to 150 cm H(2)O.
Conclusions:
No upper or lower leg saphenous vein preference could be deduced from the differences in pressure-diameter response due to loss of distensibility (and thus of compliance) in the high-pressure range. Fibrin glue effectively prevents overdistension and preserves some distensibility in the high-pressure range in both the upper and lower leg saphenous vein. This might provide a basis for clinical application of perivenous support.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure in the Leg
Preparation:
Blood Pressure
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation