Related Experiment Video
Updated: Aug 30, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
In situ revascularization with silver-coated polyester grafts to treat aortic infection: early and midterm results
Michel Batt1, Jean-Luc Magne, Pierre Alric
1Department of Vascualr Surgery, Hospital Saint Roch, Nice, France. chir-vascualire@chu-nice.fr
Purpose:
In this prospective study we analyzed the immediate and midterm outcome in patients with abdominal aorta infection (mycotic aneurysm, prosthetic graft infection) managed by excision of the aneurysm or the infected vascular prosthesis and in situ replacement with a silver-coated polyester prosthesis.
Methods:
From January 2000 to December 2001, 27 consecutive patients (25 men, 2 women; mean age, 69 years) with an abdominal aortic infection were entered in the study at seven participating centers. Infection was managed with either total (n = 18) or partial (n = 6) excision of the infected aorta and in situ reconstruction with an InterGard Silver (IGS) collagen and silver acetate-coated polyester graft. Assessment of outcome was based on survival, limb salvage, persistent or recurrent infection, and prosthetic graft patency.
Results:
Twenty-four patients had prosthetic graft infections, graft-duodenal fistula in 12 and graft-colonic fistula in 1; and the remaining 3 patients had primary aortic infections. Most organisms cultured were of low virulence. The IGS prosthesis was placed emergently in 11 patients (41%). Mean follow-up was 16.5 months (range, 3-30 months). Perioperative mortality was 15%; all four patients who died had a prosthetic graft infection. Actuarial survival at 24 months was 85%. No major amputations were noted in this series. Recurrent infection developed in only one patient (3.7%). Postoperative antibiotic therapy did not exceed 3 months, except in one patient. No incidence of prosthetic graft thrombosis was noted during follow-up.
Conclusion:
Preliminary results in this small series demonstrate favorable outcome with IGS grafts used to treat infection in abdominal aortic grafts and aneurysms caused by organisms with low virulence. Larger series and longer follow-up will be required to compare the role of IGS grafts with other treatment options in infected fields.
Insights
This study shows promising results using silver-coated polyester grafts for abdominal aortic infections, demonstrating good survival and low recurrence rates. Further research is needed to confirm these findings in larger patient groups.
Area of Science:
- Vascular Surgery
- Infectious Diseases
- Biomaterials Science
Background:
- Abdominal aortic infections, including mycotic aneurysms and prosthetic graft infections, pose significant clinical challenges.
- Effective management strategies are crucial to improve patient outcomes and reduce morbidity and mortality.
Purpose of the Study:
- To evaluate the immediate and midterm outcomes of treating abdominal aortic infections using in situ replacement with silver-coated polyester prostheses.
- To assess the efficacy of InterGard Silver (IGS) grafts in managing infected aortic aneurysms and prosthetic grafts.
Main Methods:
- A prospective study involving 27 consecutive patients with abdominal aortic infections from January 2000 to December 2001.
- Infection management involved excision of the infected aorta or prosthesis and in situ reconstruction with IGS grafts.
- Outcomes were assessed based on survival, limb salvage, infection recurrence, and graft patency.
Main Results:
- The study included 24 patients with prosthetic graft infections and 3 with primary aortic infections; most cultured organisms were of low virulence.
- Perioperative mortality was 15%, with all deaths occurring in patients with prosthetic graft infections. Actuarial survival at 24 months was 85%.
- No major amputations were recorded, and recurrent infection occurred in only 3.7% of patients. No prosthetic graft thrombosis was observed.
Conclusions:
- Preliminary results suggest favorable outcomes with IGS grafts for treating abdominal aortic infections caused by low-virulence organisms.
- The use of IGS grafts demonstrates potential for effective management of complex aortic infections.
- Larger studies and longer follow-up are necessary to compare IGS grafts with alternative treatment options.