Related Experiment Video
Updated: Jul 12, 2026

An Alternative to the Traditional Cold Pressor Test: The Cold Pressor Arm Wrap
Published on: January 16, 2014
[A 4 degrees C-1 min method of cold water immersion test for peripheral circulatory function in fingers]
T Ishitake1, K Nakagawa, J Iwamoto
1Department of Environmental Medicine, Kurume University School of Medicine.
Abstract:
To assess the validity of a new simplified cold water immersion test (4 degrees C-1 min method) for peripheral circulatory function, comparison was made with the conventional method (10 degrees C-10 min method). These two different methods of cold immersion test were applied to 23 patients with vibration disease and 24 healthy men. Observation was made on finger skin temperature by a thermistor and complaints in the hand by a 5-step self-reported scale method every minute during the test. The patterns of recovery of skin temperature after cold immersion in each group were similar in both methods. Pain in the hand in the 4 degrees C-1 min method was less than that in the 10 degrees C-10 min method. The recovery rate at 5 min in the patients with Raynaud's phenomenon was lower than that in those without Raynaud's phenomenon in the 4 degrees C-1 min method (p < 0.01). However, no significant differences were noted in 10 degrees C-10 min method. The results suggest that the new method is feasible in detecting the response of vasodilation after immersion. In the recovery rate at 5 min after immersion, near values of the sensitivity and specificity were observed between 50% cut-off values in the 4 degrees C-1 min method and 30% value in the 10 degrees C-10 min method. Thus, the 4 degrees C-1 min method is considered to be more useful to evaluate the physiological response after cold immersion than the 10 degrees C-10 min method.
Related Concept Videos
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...

