Analysis of carbohydrate-deficient transferrin (CDT) in vitreous humour as a forensic tool for detection of alcohol misuse
Related Experiment Video
Updated: Aug 30, 2026

Cell-Free DNA Extraction of Vitreous and Aqueous Humor Specimens for Diagnosis and Monitoring of Vitreoretinal Lymphoma
Published on: January 12, 2024
Adam Berkowicz1, Sven Wallerstedt, Kerstin Wall
1Department of Forensic Medicine, Göteborg University, Box 408, 405 30 Göteborg, Sweden.
Abstract:
Analysis of carbohydrate-deficient transferrin concentration in vitreous humour (VH-CDT) has recently been demonstrated to be useful for diagnosis of pre-mortal alcohol misuse, but more knowledge considering possible methodological problems is warranted. In a forensic sample we examined the stability of VH-CDT during laboratory handling as well as the possible affection of time-dependent changes of total transferrin concentrations in vitreous humour (VH-Transferrin) in the dead body on VH-CDT as indicator of alcohol misuse. By use of a commercial assay designed for serum analysis (CDTect) it was possible to measure VH-CDT with high precision, and detectable amounts were found in 20 of 21 alcoholics and in two of seven controls. The compound was demonstrated to be stable in vitreous humour during laboratory handling, since the results of the first analysis were well reproducible after 4 months storage of the specimens (rs=0.86, P=0.0002). Transferrin concentrations in vitreous humour (VH-Transferrin) correlated to the estimated time since the individual last time had been alive before the forensic examination (rs=0.57, P<0.005). However, in this small sample the discriminating property of VH-CDT as indicator of alcohol misuse was not decisively affected, whether or not the variables "VH-Transferrin" and "estimated time since the individual last time had been alive" were considered in a multivariate logistic regression analysis (minor change in the beta-coefficient from 0.57 to 0.52, P=0.086). We conclude that CDT is stable in vitreous humour during proper laboratory handling and that detection of VH-CDT is primarily a marker of alcohol misuse before death. However, the results of this study do not exclude that time-dependent changes of VH-Transferrin, possibly affecting VH-CDT, may occur in the dead body. VH-CDT analysis should thus, at present, be restricted to cases with rather short post-mortal time interval.
More Related Videos
04:36An Assay to Detect Protection of the Retinal Vasculature from Diabetes-Related Death in Mice
Published on: January 12, 2024
05:03Quantitative Analysis of Dietary Vitamin A Metabolites in Murine Ocular and Non-Ocular Tissues Using High-Performance Liquid Chromatography
Published on: December 27, 2024