Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Automatic correction of continuum background in laser-induced breakdown and Raman spectrometry
I B Gornushkin1, P E Eagan, A B Novikov
1Department of Chemistry, P.O. Box 117200, University of Florida, Gainesville, Florida 32611, USA.
Abstract:
The goal of this work was the development and evaluation of an algorithm for the approximation and automatic subtraction of continuum backgrounds in laser-induced breakdown and Raman spectra. The background correction algorithm was applied to simple and complex spectra and its effect on identification accuracy was studied. Linear correlation was used for the identification of plastic samples using both laser-induced breakdown and Raman spectra. For both techniques, the algorithm successfully eliminated continuum background without compromising spectral integrity. A significant improvement in the percentage of correct plastic identifications was observed for Raman spectra. The approach should be applicable to a wide range of background correction problems in atomic and molecular spectroscopy.
More Related Videos
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.