X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Multislice CT fluoroscopy: technical principles, clinical applications and dosimetry]
Ernesto Bissoli1, Lorenzo Bison, Eugenio Gioulis
1Dipartimento di Radiologia, Ospedale Civile di Conegliano (Treviso). bisserne@libero.it
Purpose:
The aim of this study is describing fluoroscopic techniques with multislice CT during interventional procedures. We emphasize the technical principles of the multislice CT fluoroscopy and the relative advantages in clinical application, in comparison to single slice fluoroCT and conventional CT guided procedures. Other topics are dosimetry and patient's and operator's radioprotection.
Materials And Methods:
We describe our experience in 60 cases of interventional procedures performed with CT fluoroscopy array for the TOSHIBA AQUILION-MULTI TSX-101A scanner that allows a real-time 3 slices simultaneous representation of the target: middle target slice, superior and inferior slices. Thirty nine biopsies, 5 abscess drainage, 12 shoulder arthrocentesis previous to arthro-MR and 4 hepatic neoplasm ablations have been performed during the last 9 months. For each procedure questionnaires have been used to evaluate: target organs, scan parameters, fluoroscopy techniques (continuous or spot) and total time of fluoroCT. Basing on these data and on the measurements made on a body phantom we calculated patient's and operator's radiation dose rate.
Results And Discussion:
The real-time simultaneous representation of the middle target slice and the adjacent superior and inferior slices has always allowed an immediate identification of the needle tip and direction. The use of a needle holder has been determined by the needle type, the fluoroscopy technique (continuous or spot), the type of interventional procedure and the target. In our experience freehand spot fluoroscopy approach was easier, faster and with less radiation dose rate. 24 seconds were the mean fluoroscopy time for all different CT fluoroscopy modalities and procedures. The mean absorbed equivalent dose rate to patient's skin was 5300 microSv/s while the dose to operator's body and hand was respectively 0.3 microSv/s and 30 microSv/s.
Conclusions:
Multislice CT fluoroscopy, specially if performed by spot technique, leads to an acceptable radiation dose rate to patient and operator, is user friendly and guides interventional procedures with rapidity.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography