Responsiveness of thermal sensors to nonuniform thermal environments and exercise
Leo J Thornley1, Stephen S Cheung, Gordon G Sleivert
1Environmental Ergonomics Laboratory, School of Health and Human Performance, Dalhousie University, Halifax, NS, Canada.
Background:
We investigated the utility of finger temperature, hand heat flux, and mean skin temperature as indices of overall thermal balance during nonuniform thermal manipulations combined with exercise, with a view to identifying useful feedback sites for input into personal thermal control systems.
Methods:
There were 16 subjects who performed 4 x 30 s of 120% VO2peak cycling with a 4-min recovery. During recovery, subjects either received no cooling (CON), upper-body cooling (UC), or upper-body cooling combined with leg heating (UCLH) using a multi-zone liquid conditioning garment. Heat loss during recovery was approximately equal to heat production during exercise. Skin temperature was measured on the mid-medial phalanx of the fourth finger. Heat flux was measured on the dorsum of the hand.
Results:
Neither hand heat flux or finger temperature distinguished between the two cooling conditions during any of the recovery periods, though hand heat flux was very sensitive to the onset and cessation of exercise. Mean skin temperature was significantly different (p < 0.05) during CON (34.0 +/- 0.1 degrees C), UC (32.5 +/- 0.2 degrees C), and UCLH (33.0 +/- 0.2 degrees C).
Conclusion:
Mean skin temperature may serve as a good indicator of overall heat exchange in the body, even when exposed to nonuniform thermal environments. As hand heat flux was very sensitive to the onset and cessation of exercise, it may be useful as a supplemental thermal feedback to modulate heat exchange in microclimate thermal control systems.
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Body Temperature
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Responses to Heat and Cold Stress