Related Experiment Video
Updated: Aug 30, 2026

Waste Water Derived Electroactive Microbial Biofilms: Growth, Maintenance, and Basic Characterization
Published on: December 29, 2013
The use of cyclic voltammetry to detect biofilms formed by Pseudomonas fluorescens on platinum electrodes
Maria João Vieira1, Isabel Alexandra Pinho, Salomé Gião
1Centro de Engenharia Biológica-IBQF, Universidade do Minho, 4710-057 Braga, Portugal. mjv@deb.uminho.pt
Abstract:
The development of an electrochemical detector to monitor the in situ formation of biofilms is described. The detector consisted of an electrochemical cell containing three electrodes, whose response to the application of a potential profile to the working electrode was sensitive to the amount of biofilm present on the surface. The electrochemical technique used was repetitive cyclic voltammetry. Differences between the response of the uncolonised electrode and after Pseudomonas fluorescens biofilms of different ages were grown on its surface were determined. The results show that cyclic voltammetry applied to platinum electrodes can be used to detect young biofilms. The development of the shape of the voltammogram as the potential is cycled may constitute a means of providing information on the coverage of the surface. Observation of the platinum electrodes before and after the electrochemical measurements showed that even after 30 min of recycling, most of the cells were still adhered to the surface, although some may have lost viability.
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Pulse Voltammetry