Comprehensive two-dimensional gas chromatography for fast screening of wash oils
K Sun1, W Winniford, J Griffith
1The Dow Chemical Company, Freeport, TX 77531, USA.
Abstract:
Fast screening of wash oils is demonstrated using comprehensive two-dimensional gas chromatography (GCxGC). Wash oils are used in ethylene production plants to minimize compressor fouling. The composition of a wash oil determines its effectiveness in solubilizing heavy hydrocarbons. In particular, the relative amount of 1- and 2-ring aromatics is important. The presence of oxygenates is undesirable because of adverse effects to the process. It is shown that GCxGC is well suited for this application. Species in wash oils are separated and grouped into three bands: a nonpolar aliphatics band, 1- and 2-ring aromatics band, and polyaromatics band. For a given polar secondary column, the spacing between bands in the second dimension can be adjusted in a broad range by selecting a primary column and an oven-temperature-programming rate. Integration of GCxGC peaks is evaluated using a standard GC integration program and a new GCxGC integration program. Consistent results are obtained using both programs for well-separated GCxGC peaks with relative differences for individual peak ranging from 0.04% to 1.6%. Peak responses are integrated by the GCxGC software, and the relative amounts of aromatics content and aliphatics content are estimated by peak response percent with relative standard deviations ranging from 0.15% to 2.8% (n = 3).
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...