Related Experiment Video
Updated: Aug 30, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Intra-operative tibial plateau fracture during unicompartmental knee replacement: a case report
P J H Sloper1, C B Hing, S T Donell
1Institute of Orthopaedics, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UT, UK.
Abstract:
Periprosthetic fracture is a recognised complication of joint replacement. Intra-operative fractures of the tibia during total knee replacement have been reported and classified, but there have been no reports in patients undergoing unicompartmental knee replacement. We report a case of intra-operative fracture of the medial tibial plateau during impaction of the tibial component of an Oxford unicompartmental knee replacement. This occurred following a small breach in the posterior tibial cortex during preparation of the tibial plateau for the implant. We therefore advise caution during this stage of the procedure, especially in patients who may already be at risk of intra-operative fracture.