Related Experiment Video
Updated: Aug 30, 2026

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Acoustic transmission in normal human hips: structural testing of joint symmetry
Kevin S C Kwong1, Xiaolin Huang, Jack C Y Cheng
1Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China. rsskwong@inet.polyu.edu.hk
Abstract:
An acoustical technique has been developed for the measurement of structural symmetry of the hip joints. A mild vibratory force was applied to the sacrum and sound signals were picked up at both hips by a pair of microphones installed in two stethoscopes. These stethoscope-microphone assembles were calibrated to achieve a difference in relative sensitivity of less than 0.2 dB. The relative transmission of sound signals was analysed and compared between both hips by a dual-channel signal analyser. Twenty-seven healthy adults, 20 healthy pre-school children and 19 normal neonates were tested. Results from these three groups showed high coherence of the sound signals and that the discrepancy between both hips was smallest in the frequency range of 200-315 Hz. For normal neonates, the sound signals maintained a high coherence (gamma2>0.97) and small discrepancy (D<1.25 dB) between both hips. This study has shown that the acoustical technique provides a practical structural testing for bony symmetry of the hips and the results offer a baseline for further investigation into developmental dysplasia of the hip (DDH) in neonates. Clinical screening for DDH is still problematic in developing countries.