Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Noninvasive assessment of blood pressure variability in preterm infants
Peter Andriessen1, Rick L M Schoffelen, Ralph C M Berendsen
1Neonatal Intensive Care Unit, Máxima Medical Center, PO Box 7777, 5500 MB, Veldhoven, The Netherlands. P.Andriessen@mmc.nl
Abstract:
The feasibility of measuring blood pressure (BP) variability by a noninvasive beat-to-beat finger arterial BP device (Finapres) was assessed in preterm infants. By application of the finger cuff around the infant's wrist, time and frequency domain (spectral power) analysis of noninvasive beat-to-beat BP signals were compared with intra-arterial measurements. A fast Fourier Transform was used to compute the spectral power density from 128-s periods. The low-frequency band (LF; 0.04-0.15 Hz) is partly associated with baroreflex activity. The high-frequency band (HF; 0.4-1.5 Hz) is associated with respiratory activity. In eight subjects above 1000 g, reliable signals could be obtained. We observed a high correlation between noninvasive and intra-arterial beat-to-beat systolic BP values (mean r value +/- SD, 0.87 +/- 0.11), with a gain close to 1 (mean gain +/- SD, 1.0 +/- 0.4 mm Hg/mm Hg). Finapres estimated beat-to-beat systolic BP changes more accurately than diastolic values. We found a very high amount of linear coupling, expressed as coherence function, between the power spectra of noninvasive and intra-arterial systolic BP measurements. For systolic BP, the (pooled) group mean +/- SEM coherence values were 0.93 +/- 0.00 and 0.91 +/- 0.01 for LF and HF fluctuations, respectively (NS). The wrist method of Finapres in neonates has limited value in estimating absolute BP but is useful in a clinical research situation, where identification of beat-to-beat changes in systolic BP is more important. Finapres provides a noninvasive tool for investigating autonomic cardiovascular regulation (baroreflex sensitivity, spectral analysis of BP fluctuations) in neonates.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure