Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Trace gas measurement with an integrated porous tube collector/long-path absorbance detector
Kei Toda1, Ken-Ichi Yoshioka, Shin-Ichi Ohira
1Department of Environmental Science, Faculty of Science, Kumamoto University, 2-39-1, Kurokami, Kumamoto 860-8555, Japan. todakei@sci.kumamoto-u.ac.jp
Abstract:
Porous membrane tubes filled with an absorbing solution that change colors upon selective reactions with specific gases provide high sensitivity inexpensive gas sensors. These can be routinely used for ambient monitoring in a fully automated manner. We consider both stopped and continuous flow operations and show the superiority of the stopped flow mode theoretically and experimentally. Light throughput through various membrane tubes is presented, and superior performance of such tubes over Teflon AF is shown. Sensors for NO2 and for O3 were based on Griess-Saltzman and indigotrisulfonate chemistries, respectively. A computer-controlled two-LED absorbance measurement system (one wavelength monitors the signal, the other references the system) that also governs automated reagent refilling was implemented. Sub-parts-per-billion-volume detection limits are attainable within a few minutes for both gases. Comparative data with a commercial UV-photometry-based ozone monitor showed excellent agreement with the response pattern of the present instrument. Low cost, ready applicability to the measurement of different gases by merely changing the light source and chemistry, and high sensitivity makes this instrument attractive for both pedagogic and practical purposes.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...