Related Experiment Video
Updated: Aug 30, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
Three-dimensional color power imaging of the fetal hepatic circulation
Karim Kalache1, Roberto Romero, Luis F Goncalves
1Perinatology Research Branch, National Institute of Child Health and Human Development, National Institutes of Health/DHHS, Bethesda, MD 20892, USA.
Objective:
The purpose of this study was to describe the use of three-dimensional power Doppler ultrasonography to identify vascular congenital anomalies of fetal portosystemic and umbilical venous systems.
Study Design:
In a prospective study, the hepatic and umbilical venous systems were examined in 390 fetuses with two-dimensional ultrasonography, color, and spectral Doppler imaging. Fetuses suspected to have anomalies of the portal system and ductus venosus were additionally examined with three-dimensional power Doppler ultrasonography.
Results:
Vascular anomalies were identified in 8 fetuses (absent ductus venosus, n=4; direct connection between the umbilical vein and the right atrium, n=2; and direct connection between the umbilical vein and the inferior vena cava, n=2) out of the 310 in which the venous system could be adequately imaged (prevalence=2.6%). Three-dimensional power Doppler imaging showed the course of the umbilical vein, its relationship to the portosystemic circulation, and whether a ductus venosus was present.
Conclusion:
Three-dimensional power Doppler ultrasonography can be used to image normal fetal hepatic and portal circulation, as well as identify anomalies of the fetal portosystemic and umbilical venous systems.