Related Experiment Videos
Ferrara intrastromal corneal ring segments for severe keratoconus
Danielle Miranda1, Marta Sartori, Claudia Francesconi
1Department of Ophthalmology, Federal University of São Paulo, Paulista School of Medicine, São Paulo, Brazil.
Journal of Refractive Surgery (Thorofare, N.J. : 1995)
|December 3, 2003
Summary
Ferrara intrastromal ring segments improved vision in most severe keratoconus patients. This treatment offers a potential alternative to corneal transplantation for advanced keratoconus.
Area of Science:
- Ophthalmology
- Corneal Surgery
- Vision Science
Background:
- Keratoconus is a progressive corneal ectasia leading to severe visual impairment.
- Patients with advanced keratoconus often experience disabling visual acuity and contact lens intolerance.
- Penetrating keratoplasty is a common treatment for severe keratoconus, but carries risks.
Purpose of the Study:
- To evaluate the safety and efficacy of intrastromal Ferrara ring segments in eyes with severe keratoconus.
- To assess visual acuity, refractive error, and corneal changes after Ferrara ring implantation.
- To identify potential complications associated with the procedure.
Main Methods:
- Intrastromal Ferrara ring segments were implanted in 36 eyes of 35 patients with severe keratoconus.
- Patients were evaluated at 12 months post-implantation.
- Preoperative and postoperative visual acuity, refraction, keratometry, pachymetry, and anterior chamber depth were analyzed.
Main Results:
- No patient experienced a loss of visual acuity.
- Uncorrected visual acuity improved in 77.78% of eyes, and best spectacle-corrected visual acuity improved in 80.56%.
- Mean spherical equivalent refraction improved, and corneal flattening was observed. Complications included segment extrusion in 13.8% of eyes.
Conclusions:
- Ferrara intrastromal ring segments demonstrate potential as an alternative treatment for severe keratoconus.
- The procedure showed favorable visual outcomes and corneal changes.