A Fluorescence Fluctuation Spectroscopy Assay of Protein-Protein Interactions at Cell-Cell Contacts
Published on: December 1, 2018
Two-beam fluorescence cross-correlation spectroscopy for simultaneous analysis of positive and negative ions in
1Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
Abstract:
Two-beam fluorescence cross-correlation spectroscopy was used for multicomponent electrophoretic analysis of positive and negative ions flowing continuously, and in opposite directions, through a polymer-coated electrophoresis capillary. Cross-correlation analysis of the fluorescence monitored from two spatially offset microscopic detection volumes revealed the magnitude and direction of the electrophoretic flow velocity of each analyte. This enabled resolution of a three-component mixture containing nanomolar concentrations of cationic rhodamine 6G and anionic 5-carboxytetramethylrhodamine (TAMRA) and TAMRA-labeled single-stranded DNA in aqueous buffer. The relative concentrations of each analyte, determined from the cross-correlation analysis, agreed with known values within experimental error. This technique is sensitive to molecular processes occurring on a millisecond time scale and will prove useful for monitoring rapid fluctuations in the magnitude and direction of the electrophoretic flow velocity caused by spontaneous chemical reactions or conformational transformations at thermodynamic equilibrium.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
14:12Dual-Color Fluorescence Cross-Correlation Spectroscopy to Study Protein-Protein Interaction and Protein Dynamics in Live Cells
Published on: December 11, 2021
Related Concept Videos
Flow Cytometry
In...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.