Purpose:
To determine the accuracy of the two-point Patlak plot in the calculation of glomerular filtration rate (GFR).
Materials And Methods:
Fifty patients without acute renal disorder were included. GFR was calculated by using a two-point Patlak plot technique. The computed tomography (CT) protocol consisted of a plain examination followed by two contrast material-enhanced examinations in the arterial and portovenous phase. Each examination included the entire kidneys and was performed after injection of 120 mL iopromide and 300 mg of iodine per milliliter given per 75 kg of body weight. All examinations were performed with a standard abdominal protocol. Section thickness was 4 x 2.5 mm, and table advance was 12.5 mm. Bolus triggering commenced 10 seconds after the start of contrast medium injection. Twelve dynamic scans were obtained with reduced tube current every 3 seconds to obtain sufficient arterial input function data. Correction for hematocrit level was made by using the unenhanced attenuation of the aorta. As a reference method, plasma clearance of the contrast medium injected for CT was calculated from three iodine plasma concentration measurements obtained 3, 4, and 5 hours after injection. Linear correlation was performed.
Results:
GFR was calculated from CT data in 48 patients. Two patients were excluded because of breathing errors. Mean GFR was 80 mL/min (range, 17-153 mL/min) as measured with iopromide plasma clearance and 82 mL/min (range, 28-148 mL/min) as measured with CT. Linear correlation between the two methods was r = 0.889; GFR calculated with the two-point Patlak plot was equal to 15 plus 0.83 times GFR (plasma clearance). The mean difference between GFRs as determined with the two methods was -1.2 mL/min (95% CI: -27.1, 24.6).
Conclusion:
Total GFR can be measured accurately with minimally extended triphasic CT in patients without acute renal disorder by using a two-point Patlak plot technique.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles.
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Imaging Studies III: Computed Tomography