Related Experiment Video
Updated: Aug 30, 2026

An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
[Determination of tetramine in plasma by gas chromatography]
Zhonghui Chen1, Xiaowei Ge, Jun Guo
1Institute of Occupational Medicine and Poisons Control, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
Abstract:
A method was developed to measure the tetramine in plasma by liquid-liquid extraction and GC-NPD with the limit of detection (LOD) 1.5 pg and the limit of quantity 10 ng/ml. The linear range was 0.1-5 micrograms/ml with a correlation coefficient of 0.999. Recoveries for three concentrations of tetramine were 96.0%, 107.0%, 106.8%. The intra-day precision were 9.6%, 9.8%, 7.8%, the inter-day precision were 6.6%, 8.5%, 6.2%. Tetramine in plasma was stable up to 5 months at -4 degrees C.