Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comprehensive two-dimensional gas chromatography of the 209 polychlorinated biphenyls
Mikael Harju1, Conny Danielsson, Peter Haglund
1Department of Chemistry, Institute of Environmental Chemistry, Umeå University, SE-901 87 Umeå, Sweden. mikael.harju@chem.umu.se
Abstract:
Comprehensive two-dimensional gas chromatography (GC x GC) of the 209 polychlorinated biphenyls (CBs) was carried out using a longitudinally modulated cryogenic system (LMCS) and liquid carbon dioxide as cryogen. The effluent from a non-polar column was modulated and further separated on either a polar or a shape-selective second-dimension column. Five GC x GC column combinations were evaluated, with DB-XLB as the first column in each case. DB-XLB separates more congeners than any other GC column currently available. When combined with a biscyanopropyl siloxane (SP-2340 or BPX70) or smectic liquid crystal (LC-50) second-dimension column in a GC x GC system many additional CBs can be separated. In total, 176 and 181 of the 209 congeners were separated (Rs = 0.5) on the column combinations DB-XLB/SP-2340 and DB-XLB/LC-50, respectively. Of the 136 CBs present in any Aroclor mixture at concentrations greater than 0.05% (w/w), 126 were resolved using either of these two column combinations. The seven frequently measured CBs 28, 52, 101, 118, 138, 153, 180, and the WHO-PCBs 77, 81, 105, 114, 118, 123, 126, 156. 157, 167, 169 and 189 were all separated from Aroclor CBs on the DB-XLB/LC-50 column set, whereas CBs 118 and 131 coeluted on the DB-XLB/SP-2340 column set. In addition, three technical CB formulations (Aroclors 1232, 1248 and 1260) and a seal blubber sample (Halichoerus grypus) from the Baltic Sea were analyzed. Similar peak patterns were found for Aroclor 1260 and the CBs in the seal blubber, facilitating use of this technical CB formulation to identify the CBs in the blubber by GC x GC. Individual CBs in environmental samples, such as seal blubber, may be identified semi-automatically by matching the samples GC x GC profiles to a template generated using a standard containing all 209 CBs. Using such a template, 64 CBs were identified in the grey seal blubber sample.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
12:24Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...