Sources of variability in blood pressure measurement using the Dinamap PRO 100 automated oscillometric device
Joseph J Chang1, Daniel Rabinowitz, Steven Shea
1Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
Abstract:
The Dinamap automated oscillometric device (GE Medical Systems Information Technologies, Inc., Milwaukee, Wisconsin) for blood pressure measurement is widely employed in epidemiologic studies because it is easy to use and because it eliminates observer variability. In this study, the authors assessed the variability in observed blood pressures associated with use of the Dinamap monitor and estimated the contributions of various factors to that variability. In 60 volunteers (30 aged 23-35 years and 30 aged 54-82 years) from New York, New York, the authors obtained 30 simultaneous paired blood pressure measurements in both arms at 1-minute intervals, using three separate Dinamap PRO 100 devices allocated to arm and subject according to a balanced incomplete block design. Variability, defined as the between-arm difference in blood pressure measurements, was analyzed using a mixed-effects linear regression model. A total of 1,800 paired blood pressure measurements were obtained between September 2001 and June 2002. The mean ages of the two groups were 28.3 years (standard deviation, 4.0) and 71.7 years (standard deviation, 8.0). A diagnosis of hypertension was present in 53% of the older subjects and none of the younger subjects. Fifty percent of paired simultaneous blood pressure measurements obtained were in agreement within 4 mmHg for systolic blood pressure or within 3 mmHg for diastolic blood pressure. Residual variability, attributable to the intrinsic inaccuracy of the device, accounted for 64-82% of the total systolic and diastolic blood pressure variability. The majority of variability in blood pressure measurement was due to the device as used under the study conditions.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: