Membrane oxygenator exhaust capnography for continuously estimating arterial carbon dioxide tension during
Kieron C Potger1, Darryl McMillan, Joanne Southwell
1Perfusion and Autotransfusion Unit, Department of Anaesthesia & Pain Management, Royal North Shore Hospital, Sydney, Australia. webmaster@perfusion.com.ar
Abstract:
Typically, the standard practice for measuring the arterial blood carbon dioxide tension (PaCO2) during cardiopulmonary bypass (CPB) is to take intermittent blood samples for analysis by a bench blood gas analyzer. Continuous inline blood gas monitors are available but are expensive. A potential solution is the capnograph, which was evaluated by determining how accurately the carbon dioxide tension in the oxygenator exhaust gases (PECO2) predicts PaCO2. A standard capnograph monitoring line was attached to the exhaust port of the membrane oxygenator. During CPB, the capnograph reading and arterial blood temperature were recorded at the same time as routine arterial blood gases were taken. One hundred fifty-seven blood samples were collected from 78 patients. A good correlation was found between the PECO2 and the temperature corrected PaCO2 (r2 = 0.833, P < .001). There was also a reasonable degree of agreement between the PECO2 and the temperature corrected PaCO2 during all phases of CPB: accuracy (bias or mean difference between PaCO2 and PECO2) of -1.2 mmHg; precision (95% limits of agreement) of +/- 4.7 mmHg. These results suggest that oxygenator exhaust capnography may be a simple and inexpensive adjunct to the bench blood gas analyzer in continuously estimating PaCO2 of a clinically useful degree of accuracy during CPB.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Acute Respiratory Failure-III
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: