Related Experiment Videos
Recurrent bronchobiliary fistula: unsuccessful management with repeated insertion of metallic biliary stent
Sung Il Jung1, Jin Mo Goo, Joon Koo Han
1Department of Radiology, Seoul National University College of Medicine, 28 Yongon-dong, Chongno-gu, Seoul 110-744, Korea.
Abstract:
This case of a recurrent bronchobiliary fistula was first managed temporarily with repeated metallic biliary stent placement, and finally required surgery. A 65-year-old man, who had undergone a hepatic resection for metastatic colon carcinoma, with a bronchobiliary fistula was treated with metallic biliary stent placement for a stenosis in the common bile duct. During 16 months of follow-up, the biliptysis recurred twice by a recurrent stricture of the common bile duct, which was managed by placement of a second and third stent in a coaxial manner. Three months after placement of the third stent, jaundice developed and the patient finally underwent a Roux-en-Y choledochojejunostomy.