Energy expenditure in human milk- versus formula-fed preterm infants

Ronit Lubetzky1, Nachum Vaisman, Francis B Mimouni

  • 1Department of Neonatology, Lis Maternity Hospital, Tel Aviv Sourasky Medical Center, and the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.

The Journal of Pediatrics
|December 6, 2003
PubMed

Insights

Preterm infants fed breast milk showed lower energy expenditure (EE) compared to those fed preterm infant formula. This finding highlights differences in metabolic response to human milk versus formula in premature infants.

Area of Science:

  • Neonatal Nutrition
  • Pediatric Metabolism
  • Infant Physiology

Background:

  • Preterm infants require specialized nutrition for optimal growth and development.
  • Understanding energy expenditure (EE) is crucial for managing nutritional needs in premature infants.
  • Human milk and preterm infant formula differ in composition, potentially affecting infant metabolism.

Purpose of the Study:

  • To compare the energy expenditure (EE) of preterm infants when fed mother's milk versus preterm infant formula.
  • To investigate the metabolic impact of different feeding strategies in premature infants.

Main Methods:

  • A prospective, randomized crossover study involving 13 healthy preterm infants.
  • Infants received alternating 24-hour periods of human milk and preterm infant formula.
  • Energy expenditure was measured using indirect calorimetry during sleep, pre-feeding, during feeding, and post-feeding.

Main Results:

  • Energy expenditure was significantly lower in preterm infants fed human milk compared to preterm infant formula across all measurement periods (prefeeding, during feeding, postfeeding).
  • Statistical significance (P<.05) was maintained for prefeeding and during-feeding measurements.
  • After correcting for actual energy intake, all observed differences in EE reached statistical significance (P<.05).

Conclusions:

  • Preterm infants exhibit lower energy expenditure when nourished with breast milk compared to preterm infant formula.
  • This suggests a potentially greater metabolic efficiency or different substrate utilization with human milk in preterm infants.
Abstract

Related Concept Videos

Metabolic Rate01:25

Metabolic Rate

The human body is a powerhouse of energy, with every cell performing numerous functions that require energy. This energy production and consumption is measured by the metabolic rate, which quantifies the total heat generated by all the body's chemical reactions and mechanical work. This measurement helps to determine the rate of kilocalorie (kcal) consumption needed to fuel all ongoing activities.
The Basal Metabolic Rate (BMR) measures the energy expended at rest.
Several factors influence the...
Body Temperature01:25

Body Temperature

The body's temperature, measured in degrees, is determined by the balance between heat production and dissipation to the surrounding environment. For instance, if exercising vigorously, the body will produce more heat, causing sweat and dissipating that heat. Despite extreme environmental conditions and physical exertion, the human temperature-control system maintains a constant core body temperature (the temperature of deep tissues, which are the tissues located beneath the skin and other...
Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...