[Tissue pressure in patients with phlebogenic edema]
V Ia Zolotorevskiĭ1, M M Aliev, Kh M Khasaev
1Medical Unit No. 32, A. V. Vishnevsky Institute of Surgery, Russian Academy of Medical Sciences, Moscow, Russia.
This study measured tissue pressure in patients with lower extremity varicosity and phlebogenic edema. Many patients showed impaired tissue fluid absorption, indicating potential microcirculatory issues.
Area of Science:
- Vascular Medicine
- Dermatology
- Physiology
Background:
- Lower extremity varicosity frequently leads to phlebogenic edema.
- Assessing tissue fluid dynamics is crucial for understanding edema progression.
Observation:
- Tissue pressure was measured using the Emmet technique in the subcutaneous fat of 31 patients with lower extremity varicosity and edema.
- Changes in tissue pressure and the rate of fluid resorption were recorded after needle impaction.
Findings:
- 16% of patients had normal tissue fluid absorption, 39% showed accelerated absorption, and 45% exhibited decelerated absorption.
- Decelerated resorption correlated with a higher incidence of chronic edema.
- Saline resorption rates in healthy individuals were over 4.8 times higher than tissue fluid absorption rates; this ratio increased significantly in deep vein valvular insufficiency.
Implications:
- Cessation of fluid or saline resorption indicates microcirculatory swelling.
- The Emmet technique aids in diagnosing latent edema and objectively evaluating treatment responses.
- This method can inform surgical decisions for phlebectomy, assess surgical outcomes, and enable early detection of disease recurrence.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure in the Leg
Preparation:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Artery Disease V: Postoperative Nursing Management