Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Automated method for subtraction of fluorescence from biological Raman spectra
Chad A Lieber1, Anita Mahadevan-Jansen
1Department of Biomedical Engineering, Vanderbilt University, Station B, Box 351631, Nashville, Tennessee 37235, USA.
Abstract:
One of the challenges of using Raman spectroscopy for biological applications is the inherent fluorescence generated by many biological molecules that underlies the measured spectra. This fluorescence can sometimes be several orders of magnitude more intense than the weak Raman scatter, and its presence must be minimized in order to resolve and analyze the Raman spectrum. Several techniques involving hardware and software have been devised for this purpose; these include the use of wavelength shifting, time gating, frequency-domain filtering, first- and second-order derivatives, and simple curve fitting of the broadband variation with a high-order polynomial. Of these, polynomial fitting has been found to be a simple but effective method. However, this technique typically requires user intervention and thus is time consuming and prone to variability. An automated method for fluorescence subtraction, based on a modification to least-squares polynomial curve fitting, is described. Results indicate that the presented automated method is proficient in fluorescence subtraction, repeatability, and in retention of Raman spectral lineshapes.
More Related Videos
07:37An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020
06:12Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
Published on: March 17, 2023
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...