Related Experiment Video
Updated: Aug 29, 2026

Biosensor-based High Throughput Biopanning and Bioinformatics Analysis Strategy for the Global Validation of Drug-protein Interactions
Published on: December 1, 2020
Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic
Binodh DeSilva1, Wendell Smith, Russell Weiner
1Amgen Inc, Thousand Oaks, California, USA.
Purpose:
With this publication a subcommittee of the AAPS Ligand Binding Assay Bioanalytical Focus Group (LBABFG) makes recommendations for the development, validation, and implementation of ligand binding assays (LBAs) that are intended to support pharmacokinetic and toxicokinetic assessments of macromolecules.
Methods:
This subcommittee was comprised of 10 members representing Pharmaceutical, Biotechnology, and the contract research organization industries from the United States, Canada, and Europe. Each section of this consensus document addresses a specific analytical performance characteristic or aspect for validation of a LBA. Within each section the topics are organized by an assay's life cycle, the development phase, pre-study validation, and in-study validation. Because unique issues often accompany bioanalytical assays for macromolecules, this document should be viewed as a guide for designing and conducting the validation of ligand binding assays.
Results:
Values of +/- 20% (25% at the lower limit of quantification [LLOQ]) are recommended as default acceptance criteria for accuracy (% relative error [RE], mean bias) and interbatch precision (%coefficient of variation [CV]). In addition, we propose as secondary criteria for method acceptance that the sum of the interbatch precision (%CV) and the absolute value of the mean bias (%RE) be less than or equal to 30%. This added criterion is recommended to help ensure that in-study runs of test samples will meet the proposed run acceptance criteria of 4-6-30. Exceptions to the proposed process and acceptance criteria are appropriate when accompanied by a sound scientific rationale.
Conclusions:
In this consensus document, we attempt to make recommendations that are based on bioanalytical best practices and statistical thinking for development and validation of LBAs.
More Related Videos
Related Concept Videos
The Equilibrium Binding Constant and Binding Strength
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Measurement of Bioavailability: Pharmacodynamic Methods

