Determination of flunixin in edible bovine tissues using liquid chromatography coupled with tandem mass spectrometry
Pamela L Boner1, Dave D W Liu, William F Feely
1XenoBiotic Laboratories, Inc., 107 Morgan Lane, Plainsboro, New Jersey 08536, USA. pboner@xbl.com
Abstract:
An accurate, reliable, and reproducible assay was developed and validated to determine flunixin in bovine liver, kidney, muscle, and fat. The overall recovery and percent coefficient of variation (%CV) of twenty-eight determinations in each tissue for flunixin free acid were 85.9% (5.9% CV) for liver, 94.6% (9.9% CV) for kidney, 87.4% (4.7% CV) for muscle, and 87.6% (4.4% CV) for fat. The theoretical limit of detection was 0.1 microg/kg (ppb, ng/g) for liver and kidney, and 0.2 ppb for muscle and fat. The theoretical limit of quantitation was 0.3, 0.2, 0.6, and 0.4 ppb for liver, kidney, muscle, and fat, respectively. The validated lower limit of quantitation was 1 ppb for edible tissues with the upper limit of 400 ppb for liver and kidney, 100 ppb for fat, and 40 ppb for muscle. Accuracy, precision, linearity, specificity, ruggedness, and storage stability were demonstrated. Briefly, the method involves an initial acid hydrolysis, followed by pH adjustment ( approximately 9.5) and partitioning with ethyl acetate. A portion of the ethyl acetate extract was purified by solid-phase extraction using a strong cation exchange cartridge. The eluate was then evaporated to dryness, reconstituted, and analyzed using LC/MS/MS. The validated method is sensitive and specific for flunixin in edible bovine tissue.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013