The acoustic spectrophonometer: a novel bioanalytical technique based on multifrequency acoustic devices
A C Stevenson1, B Araya-Kleinsteuber, R S Sethi
1Institute of Biotechnology, University of Cambridge, Tennis Court Road, Cambridge, UK CB2 1QT.
Abstract:
A measurement technique similar to optical absorption spectroscopy but based on evanescent acoustic waves is described in this paper. This format employs a planar spiral coil to vibrate a single crystal of quartz from 6 to 400 MHz, in order to measure multifrequency acoustic spectra. Consistency with the defined Sauerbrey and Kanazawa terms K1 and K2 when applied to multiple frequencies was found for these specific operating conditions in terms of a significant fit between the measured and calculated values: For an IgG surface density of 13.5 ng mm(-2) the measured value of K1 is 22.5 x 10(-6) and the calculated value is 20.4 x 10(-6), whilst for glycerol viscous loadings of 5.131 cP the measured value of K2 is 0.47 and the calculated value is 0.54. Thus for these specific surface loadings the multifrequency data fits to the predictions of the Sauerbrey model to within 10% and to Kanazawa model within 13%. However collective frequency shifts for 5.131 cP solutions of sucrose, dextran and glucose were found to exhibit an unanticipated additional variability (R2 < 0.4) with frequency, but retained a square root of frequency dependency within a factor 2 of the interpolated K2 values. The response to the 5.131 cP dextran solution was found to be significantly below the other isoviscous solutions, with a substantially reduced frequency shift and K2 value than would be expected from its bulk viscosity. In comparison with these viscous solutions, IgG protein films consistently produced linear frequency shifts with little scatter (R2 > 0.96) that were proportional to the operating frequency, and fully consistent with the Sauerbrey model under these specific conditions. A t-test value of 14.52 was calculated from the variance and mean of the two groups, and demonstrates that the acoustic spectrophonometer can be used to distinguish between the acoustic impedance characteristics of two chemical systems that are not clearly differentiable at a single operating frequency.
Related Concept Videos
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Fluorescence Spectroscopy