Related Experiment Video
Updated: Aug 29, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Fast volatile organic compound recovery from soil standards for analysis by thermal desorption gas chromatography
Maria de Fátima Guadalupe Meniconi1, R Parris, C L P Thomas
1Research and Development Centre, Petrobras SA., Av. Um, Quadra 7, Cidade Universitaria-Ilha do Fundão, Rio de Janeiro, R.J.-CEP: 21949-900, Brazil. kvsri@dalton.ncl.res.in
Abstract:
The development of high-throughput environmental screening assays are needed to meet high-specification data quality objectives (DQOs) that require large numbers of samples to be taken and analysed rapidly. The acquisition and stabilisation of the sample is a key technical and operational challenge in analytical sequences associated with the determination of volatile organic compound (VOC) contamination of soils. Further the development of miniaturised and embedded analytical systems for environmental conditioning monitoring requires the development of new sampling techniques. A proof-of-concept study is described that shows how pressurised gas, in this case carbon dioxide, may be used to recover reversibly-bound VOCs from soil into an adsorbent sampler, and then analysed by thermal desorption-gas chromatography. The effects of the volume of the pressurised gas, the gas flow rate and the mass of the soil sample on the recovery efficiency and breakthrough from the adsorbent trap were investigated in a preliminary characterisation study. Two distinct approaches were identified. The first involved ventilation of the voids within the soil matrix to displace the soil-gas headspace, a rapid screening approach. The second involved a more prolonged purge of the matrix to strip reversibly bound species into the gas phase and hence pass them into the adsorbent trap, a purge and trap approach. The shortest possible sample processing time required to yield analytically useful responses was 5 s with the use of the headspace approach. In this case n-octane, benzene and toluene were recovered from conditioned spiked soil samples at concentrations in the range 42 to 1690 mg kg(-1). The limit of detection for the system was estimated to be no greater than 1.2 mg kg(-1). Using the purge and trap variant enabled recovery efficiencies greater than 93% to be achieved with liquid spikes of n-octane onto soil samples. These preliminary studies showed that a system based on this approach would need to balance recovery efficiency, time and analyte breakthrough from the adsorbent trap.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Volatilization
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II