Related Experiment Video
Updated: Aug 29, 2026

Electrospinning Fundamentals: Optimizing Solution and Apparatus Parameters
Published on: January 21, 2011
Technique paper for wet-spinning poly(L-lactic acid) and poly(DL-lactide-co-glycolide) monofilament fibers
Kevin D Nelson1, Andres Romero, Paula Waggoner
1Joint Program in Biomedical Engineering, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas 76019-0138, USA. knelson@uta.edu
Abstract:
A simple and repeatable method is described for wet-spinning poly(L-lactic acid) (PLLA) and poly(DL-lactic-co-glycolic acid) (PLGA) monofilament fibers. These fibers are strong, elastic, and suitable for many applications, including use as tissue-engineering scaffolds. The PLLA wet-extruded fibers do not show additional strain-induced crystallization as a result of drawing the fibers during fabrication; however, there is an apparent increase in crystallinity late in the degradation process in saline at 37 degrees C. We have measured the molecular weight degradation in saline at 37 degrees C for fibers of both PLLA and PLGA. Changing solvent systems, polymer blends, and winding rates alters mechanical and morphological properties of these fibers for specific applications. The authors discuss a possible theoretical explanation for these observed changes due to changes in polymer concentration, solvent system, and coagulation bath properties. This wet-extrusion process is simple and inexpensive enough to be carried out in almost any laboratory interested in tissue engineering.