Disinfection of hospital wastewater by continuous ozonization
Chow-Feng Chiang1, Ching-Tsan Tsai, Shaw-Tao Lin
1Institute of Environmental Health, China Medical College, Taichung, Taiwan.
Abstract:
The disinfection of hospital wastewaters using the ozonization process was studied. The concentrations of ozone required to reach a sudden drop of coliform and Pseudomonas aeruginosa in the wastewater are 4.0-7.0 and 3.0-5.0 mg L(-1), respectively. For the hospital wastewater, the disinfection efficiencies were 0.518S(-1.1) for coliforms, 0.509S(-1.06) for Pseudomonas aeruginosa and 0.254S-(1.54) for total count, respectively. As to the effects of ozone input methods on the disinfection efficiency, the continuous ozonization process was ten times higher than the batch input process. The low COD removal rate was obtained at 25.0 mgL(-1) of ozone concentration for hospital wastewater. However, more biodegradable compounds resulted in the treated mixture.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
14:17The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Biological Treatment of Effluent and Waste Water
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Microbial Wastewater Treatment
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...