Related Experiment Video
Updated: Aug 29, 2026

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
Published on: April 29, 2011
Ventilation-perfusion distribution related to different inspiratory flow patterns in experimental lung injury
Rolf Dembinski1, Dietrich Henzler, Ralf Bensberg
1From the Department of Anesthesiology, University Hospital of the RWTH Aachen, Pauwelsstrasse 30, 52074 Aachen, Germany.
Unlabelled:
In acute lung injury (ALI), controlled mechanical ventilation with decelerating inspiratory flow (.V(dec)) has been suggested to improve oxygenation when compared with constant flow (.V(con)) by improving the distribution of ventilation and perfusion (.V(A)/.Q). We performed the present study to test this hypothesis in an animal model of ALI. Furthermore, the effects of combined decelerating and constant flow (Vdot;(deco)) were evaluated. Thus, 18 pigs with experimental ALI were randomized to receive mechanical ventilation with either .V(con), .V(dec) or a fixed combination of both flow wave forms (.V(deco)) at the same tidal volume and positive end-expiratory pressure level for 6 h. Hemodynamics, gas exchange, and .V(A)/.Q distribution were determined. The results revealed an improvement of oxygenation resulting from a decrease of pulmonary shunt within each group (P < 0.05). However, blood flow to lung areas with a normal .V(A)/.Q distribution increased only during ventilation with .V(con) (P < 0.05). Accordingly, PaO(2) was higher with .V(con) than with .V(dec) and .V(deco) (P < 0.05). We conclude that contrary to the hypothesis, .V(con)provides a more favorable .V(A)/.Q distribution, and hence better oxygenation, when compared with .V(dec) and .V(deco) in this model of ALI.
Implications:
In acute lung injury, mechanical ventilation with decelerating flow has been suggested to improve ventilation-perfusion distribution when compared with constant flow. We tested this hypothesis in an animal model. Contrary to the hypothesis, we found a more favorable ventilation-perfusion distribution during constant flow when compared with decelerating flow.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Atelectasis II: Pathophysiology
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...