Abstract:
The voltammetry of 7,7,8,8-tetracyanoquinodimethane (TCNQ) at an electrode-microparticle-aqueous (electrolye) interface has been proposed as a cation sensor on the basis that changes in electrolyte cation (analyte) concentrations result in reproducible shifts in the TCNQ0/- reversible potential. In order to probe the ion selective nature of the TCNQ sensor, the voltammetric response towards a series of tetraalkylammonium cations of variable size and hydrophobicity were studied. Both the thermodynamics (reversible potential) and kinetics (voltammetric peak separation) of the TCNQ0/- system were strongly dependant on the identity of the R4N+ cation. The reversible potential responded in a Nernstian manner to changes in cation concentration. When presented with mixed-analyte solutions, the TCNQ system exhibited Nicolsky type (or competitive) form of selectivity. However, the selectivity coefficients found in the present study were far greater than previously reported with group I cations. The order obtained for the tetraalkylammonium series indicates that ion selectivity is predominantly based on analyte solvation thermodyanics rather than a specific ionophore mechanism.
More Related Videos
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
EDTA: Auxiliary Complexing Reagents
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Electrodeposition
Electrodeposition can...