Comparison of linear and nonlinear regression for modeling the first-order degradation of pest-control substances in

Rod A Herman1, Peter N Scherer

  • 1Dow AgroSciences LLC, 9330 Zionsville Road, Indianapolis, Indiana 46268, USA. raherman@dow.com

Related Concept Videos

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Linear Approximations01:23

Linear Approximations

For a differentiable function of two variables, linear approximation estimates values near a known point by replacing the curved surface with its tangent plane. Consider the function\begin{equation*}f(x,y)=x^2+3y^2\end{equation*}near the point (2, 1). The exact value at this point is f(2, 1) = 22 + 3(1)2 = 4 + 3 = 7.The linear approximation of f(x, y)) near (a, b) is\begin{equation*}L(x,y)=f(a,b)+f_x(a,b)(x-a)+f_y(a,b)(y-b)\end{equation*}First, compute the partial derivatives: fx(x, y) = 2x and...
Nonlinear Pharmacokinetics: Overview01:19

Nonlinear Pharmacokinetics: Overview

Nonlinear or dose-dependent pharmacokinetics is a phenomenon that occurs when the pharmacokinetic parameters of certain drugs deviate from linear pharmacokinetics at higher doses. These drugs do not follow the expected first-order kinetics, where the rate of drug elimination is directly proportional to the drug concentration. Instead, they exhibit a nonlinear relationship, which can be attributed to several factors.
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Multiple Regression01:25

Multiple Regression

Multiple regression assesses a linear relationship between one response or dependent variable and two or more independent variables. It has many practical applications.
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.