Endotracheal tube intraluminal volume loss among mechanically ventilated patients
1Pulmonary and Critical Care Division, Washington University School of Medicine, St. Louis, MO 63110, USA.
Objective:
To measure endotracheal tube intraluminal volume loss among mechanically ventilated patients.
Design:
Prospective observational study.
Setting:
Medical intensive care unit (19 beds) of an urban university-affiliated teaching hospital.
Patients:
A total of 101 patients with acute respiratory failure requiring >24 hrs of mechanical ventilation.
Interventions:
None.
Measurements And Main Results:
Acoustic reflectometry was employed to measure the intraluminal volume of 13-cm endotracheal tube segments. The endotracheal tube segment volumes were statistically smaller among endotracheal tubes used in patients compared with unused endotracheal tubes (5.4 +/- 0.7 vs. 6.0 +/- 0.6 mL, p <.001). The average percentage difference in endotracheal tube segment volumes, between the unused endotracheal tubes and the endotracheal tubes used in patients, was 9.8% (range, 0-45.5%). The percentage difference in the endotracheal tube segment volumes increased significantly with increasing duration of tracheal intubation (r2 =.766, p <.001). The minimum diameter of the endotracheal tube segments was also statistically smaller among endotracheal tubes used in patients compared with the unused endotracheal tubes (7.5 +/- 0.4 vs. 6.7 +/- 1.2 mm, p <.001).
Conclusions:
Endotracheal tube intraluminal volume loss is common among patients with acute respiratory failure requiring mechanical ventilation and increases with prolonged tracheal intubation.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...