Reliability of splenic index to assess splenic involvement in pediatric Hodgkin's disease
Related Experiment Video
Updated: Aug 29, 2026

Robot-Assisted Laparoscopic Splenectomy In Children: A Case Report with Literature Review
Published on: March 27, 2026
Banu Aygun1, Sabiha P Karakas, John Leonidas
1Division of Pediatric Hematology/Oncology and Stem Cell Transplantation, Schneider Children's Hospital, Albert Einstein College of Medicine, New Hyde Park, New York 11040, USA.
Abstract:
The purpose of this study was to determine the reliability of the splenic index (SI) in children with Hodgkin's disease (HD). Seventeen patients who underwent staging laparotomy for HD were included in this study. Pretreatment computed tomography scans of these patients were reviewed retrospectively to determine the SI. The specificity, sensitivity, positive and negative predictive values, and accuracy of the SI were calculated. The sensitivity and specificity of the SI were 50% and 66%, respectively. The SI alone accurately identified or ruled out involvement with HD in 10 of 17 patients. Positive and negative predictive values of the SI were 57% and 60%, respectively. Even with the use of the SI, computed tomography alone remains unreliable to determine splenic involvement in children with HD. Additional imaging studies, especially fluorodeoxyglucose positron emission tomography, may improve the clinical staging of HD.