Normative data for a user-friendly paradigm for pattern electroretinogram recording.

Vittorio Porciatti1, Lori M Ventura

  • 1Bascom Palmer Eye Institute, Miami, Florida 33136, USA. vporciatti@med.miami.edu

Ophthalmology
|January 9, 2004
PubMed
Summary

This study introduces the Pattern Electroretinogram for Glaucoma (PERGLA) screening method, providing reliable and easy-to-interpret results for glaucoma detection. The PERGLA paradigm offers a valuable tool for objective glaucoma screening and monitoring.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Preclinical Assessment of Mitochondrial-Targeted ND4 Gene Therapy for Leber Hereditary Optic Neuropathy.

Investigative ophthalmology & visual science·2025
Same author

Topical WIN 55 212-2 Confers Long-Term Intraocular Pressure-Independent Neuroprotection in the DBA/2J Mouse Model of Glaucoma.

Ophthalmology science·2025
Same author

IC100, a humanized therapeutic monoclonal anti-ASC antibody alleviates oxygen-induced retinopathy in mice.

Angiogenesis·2024
Same author

Mitochondrially Targeted Gene Therapy Rescues Visual Loss in a Mouse Model of Leber's Hereditary Optic Neuropathy.

International journal of molecular sciences·2023
Same author

The Inflammasome-Dependent Dysfunction and Death of Retinal Ganglion Cells after Repetitive Intraocular Pressure Spikes.

Cells·2023
Same author

Editorial: Innovation in ocular pharmacology.

Frontiers in pharmacology·2023

Area of Science:

  • Ophthalmology
  • Neuroscience
  • Medical Imaging

Background:

  • Glaucoma screening requires reliable and objective methods.
  • The pattern electroretinogram (PERG) is a valuable electrophysiological test for assessing retinal function.
  • Optimizing PERG protocols for specific clinical applications like glaucoma screening is crucial.

Purpose of the Study:

  • To establish normative data for a user-friendly pattern electroretinogram (PERG) paradigm, termed PERGLA, specifically designed for glaucoma screening.
  • To validate the reliability and ease of use of the PERGLA protocol.

Main Methods:

  • A prospective, nonrandomized case series involving 93 normal subjects aged 22-85 years.
  • PERG was recorded using a Ganzfeld bowl with a reversing black-white grating stimulus.

Related Experiment Videos

  • Skin cup electrodes were used for simultaneous bilateral recording with undilated pupils.
  • Main Results:

    • The PERGLA paradigm demonstrated a high signal-to-noise ratio (>13:1) and low variability (intrasession <10%, intersession <2%).
    • Interocular asymmetry was minimal, with CVs of 9.8% for amplitude and 1.5% for phase.
    • PERG amplitude and phase showed a decrease with age, with age-corrected confidence limits established.

    Conclusions:

    • The PERGLA paradigm provides reliable electrophysiological responses comparable to standard protocols.
    • The ease of execution and interpretation of PERGLA results suggest its potential for objective glaucoma screening.