[Investigation of the entrance dose of standardized chest radiographs]
F-E Stieve1, H Gfirtner, E M Jung
1Institut für Strahlenhygiene, Bundesamt für Strahlenschutz, Oberschleissheim. fstieve@bfs.de
Abstract:
In 50 chest radiographs obtained in PA projection with the patient erect and the radiographic techniques kept constant, entrance dose, entrance surface dose and dose area product were measured and compared with the measurements obtained with Plexiglas and Alderson phantoms. Following the recommendations of the International Commission on Radiological Protection, the "absorbed dose in air" at the point of intersection of the X-ray beam with the surface of the patient was used as reference. For patients with the same diameter, the measured dose deviated up to +/- 50 % from the "Reference Man" according to the ICRP 23 as well as from the "Representative Patient" according to the ICRP 73. The exposure data produced by the equipment corresponded to the measured values with minor deviations, but the dose values expressed as entrance surface dose showed major deviation in comparison with the entrance dose due to differences in the back-scatter factor. The values of entrance dose calculated from the dose area product measurements showed additional uncertainties due to different field sizes. Moreover, a sex-specific dose area product value was identified. These results reveal that the values of the "ICRP Reference Man" differ in many situations from the values produced by the examined patient due to differences in radiation transmission. This has consequences for determining diagnostic reference values and investigating recorded radiation exposure. This will be explained and substantiated.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT