Peripheral pulse pressure responses to postural stress do not reflect those at the carotid artery
Craig D Steinback1, Deborah D O'Leary, Simon S Wang
1Neurovascular Research Laboratory, School of Kinesiology, The University of Western Ontario, London, Ontario, Canada.
Objective:
Interpretation of baroreflex cardiovascular control requires accurate assessment of pulse pressure (PP) in central arteries under conditions of varying systemic or hydrostatic pressure. The objective of this study was to examine whether changes in PP during postural stress were similar in the peripheral versus carotid arteries.
Design:
Protocol A: Pulse pressure was measured in both the left (Millar tonometer) and right (Colin Pilot) radial arteries, and in the finger (Finapres) in seated subjects (n = 7) who performed Valsalva's manoeuvre. Protocol B: PP was measured from the carotid (Millar tonometer), and from the finger and wrist kept at the level of the carotid artery, during supine and 60 degrees head-up postures.
Results:
Protocol A: Pulse pressures during Valsalva's manoeuvre were highly correlated between all devices (r = 0.6-0.8). Protocol B: compared with supine, PP was reduced in both the finger and wrist during head-up-tilt (HUT) (P<0.05), but not in the carotid artery.
Conclusions:
During Valsalva manoeuvers the Millar and Colin tonometers similarly tracked PP over a wide range of rapidly changing pressures. This observation provided confidence for the further use of the hand-held device for central measurements during changes in posture. The results from Protocol B indicate that peripheral PP measurements are not suitable surrogates for carotid pulse pressures during HUT.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical indicator...
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Blood Pressure