Photometry in the workplace: the rationale for a new method.
B Piccoli1, G Soci, P L Zambelli
1Department of Occupational Health, Universita' Degli Studi, University of Milan, Via S Barnaba 8, Milan 20122, Italy.
The Annals of Occupational Hygiene
|January 14, 2004
Summary
Traditional workplace lighting assessments using illuminance are insufficient for near work. A new method measuring luminance in the visual field provides a more accurate evaluation of natural and artificial light exposure.
Area of Science:
- Occupational health
- Lighting engineering
- Visual ergonomics
Background:
- Workplace lighting assessment traditionally relies on illuminance measurements.
- Illuminance may not adequately represent the light experienced during near work tasks.
- A new approach is needed to evaluate lighting conditions in detail for specific work situations.
Purpose of the Study:
- To describe a novel method for evaluating natural and artificial light in near work.
- To assess the role of luminance measurement in understanding workplace lighting.
- To provide a more accurate method for evaluating visual conditions in offices.
Main Methods:
- The method involves identifying visual targets, defining the visual field, measuring luminance, and creating iso-luminance maps.
- Luminance measurements pinpoint primary and secondary light sources within the visual field.
- Luminance ratios are calculated and compared for analysis.
Main Results:
- Illuminance measurements were found to be inadequate for evaluating near work lighting.
- Luxmeters integrate light over a wide angle, which is not representative of the focused visual input during near work.
- The operator's retina is primarily stimulated by light from objects within the occupational visual field.
Conclusions:
- Detailed luminance measurement in the occupational visual field aligns with visual physiology.
- This method can aid in risk assessment for visual disturbances.
- It provides a rational basis for optimizing workstation lighting.
More Related Videos
Related Concept Videos
Spectrophotometry: Introduction
8.5K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
8.5K
Photoluminescence: Applications
1.3K
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Flame Photometry: Overview
2.1K
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
2.1K
Flame Photometry: Lab
1.3K
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.3K