Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
Doppler studies evaluating the effect of a physical therapy screening protocol on vertebral artery blood flow
C Arnold1, R Bourassa, T Langer
1School of Physical Therapy, University of Saskatchewan, 210-1121 College Drive, Saskatoon, Sask S7N 0W3, Canada. arnoldc@sask.usask.ca
Abstract:
General and isolated cervical positional tests are used to screen for potential vertebro-basilar insufficiency (VBI). There is limited research evaluating vertebral artery blood flow in these positions to justify the rationale of progressive mechanical stress occurring to the arteries. The purpose of the study was to determine vertebral artery blood flow in six cervical positions used in clinical practice. A comprehensive cervical assessment was conducted on 22 men and women (mean age 35) with no known vascular pathology. Vertebral artery peak systolic (PS), end diastolic (ED) flow rates and resistive index (RI) were measured using duplex colour Doppler sonography (sampling at C3-C5) in neutral, rotation, extension, combined rotation-extension, combined rotation-extension-traction, deKelyn's position and a C1-C2 pre-manipulative hold. Results showed there was a significant decrease in PS and ED in the contra-lateral artery during the pre-manipulative hold, and a decrease in ED in the contra-lateral artery during rotation. There was no effect of age, gender or mobility restriction on these blood flow changes. The pre-manipulative hold had the greatest response with 34% of the arteries demonstrating a complete cessation of ED flow. In conclusion the pre-manipulative hold and rotation created the greatest mechanical stress to the contra-lateral vertebral artery. These two positions may be useful screening positions to identify individuals at risk for VBI due to inadequate collateral blood flow.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)