Should the gas outlet port on membrane oxygenators be routinely scavenged during cardiopulmonary bypass?
S E McNulty1, R Bartkowski, T Schmitz
1Department of Anesthesiology, Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107.
Abstract:
Elimination of a volatile anesthetic agent administered prior to the start of bypass through the oxygenator has not been previously described. The purpose of this study was to determine the contamination risk from enflurane used before but not during cardiopulmonary bypass. Enflurane concentration was measured from the gas outlet port of a membrane oxygenator using infrared gas analysis in 11 cardiac surgical patients. The mean peak concentration at the gas outlet port in patients who had a final end-tidal concentration of < or = 0.3% was 0.08 +/- 0.04%, compared to 0.18 +/- 0.05% in patients with a final end-tidal concentration of more than 0.3%, P < 0.001. The elapsed time to reach peak concentration was 8.3 +/- 8.4 minutes, whereas the elapsed time from the peak concentration to 50% of the peak level was 63.1 +/- 25.1 minutes. At the time of peak enflurane release, a concentration of less than 2 ppm was measured at distances of 10 cm or less from the oxygenator gas outlet port in patients with an end-tidal enflurane of < or = 0.3%. In one patient with a final end-tidal enflurane of 1.1%, a contaminant level of 2 ppm could be measured at 95 cm from the oxygenator gas outlet port. This demonstrates that there is a potential risk of contamination from volatile anesthetics used immediately prior to extracorporeal circulation. Minimizing this risk may necessitate routine scavenging of the oxygenator, or simply avoiding increased concentrations of inhalation anesthesia before initiating cardiopulmonary bypass.
More Related Videos
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
05:25Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management